Eaton EPM6052V-12R-042DR 1 W DC-DC Module, 5V Input
Eaton EPM6052V-12R-042DR 1 W DC-DC Module, 5V Input

Eaton EPM6052V-12R-042DR 1 W DC-DC Module, 5V Input

Share
EPM6052V-12R-042DR: Isolated DC-DC Converter, 5 V input, ±12 V output, ±42 mA, 0.5 W, 80 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6052V-12R-042DR 1 W DC-DC Module, 5V Input

    EPM6052V-12R-042DR at a glance: Isolated DC-DC Converter, 5 V input, ±12 V output, ±42 mA, 0.5 W, 80 % typical efficiency.

    Electrical Specifications

    ParameterValue
    Orderable part numberEPM6052V-12R-042DR
    Input voltage range5 Vdc
    Output voltage±12 Vdc
    Output current at full load±42 mA
    Output power0.5 W
    Efficiency, minimum77 %
    Efficiency, typical80 %
    Capacitive load, maximum220 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    Reading the Data Sheet

    This is the dual-output version of the standard 1 W isolated module: same pin pitch, same isolation barrier, two rails out. The output current is quoted per rail, and the total still has to stay inside the watt rating.

    At 0.504 W out and 80 % typical efficiency the module dissipates about 0.13 W. That is the number the thermal design has to carry, not the output power.

    Series Positioning

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    How good is the negative rail?
    Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.