EPM6052V-15R-034DR: Isolated DC-DC Converter, 5 V input, ±15 V output, ±34 mA, 0.51 W, 80 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6052V-15R-034DR Dual Output Isolated Converter

    EPM6052V-15R-034DR at a glance: Isolated DC-DC Converter, 5 V input, ±15 V output, ±34 mA, 0.51 W, 80 % typical efficiency.

    Specification Table

    ParameterValue
    Orderable part numberEPM6052V-15R-034DR
    Input voltage range5 Vdc
    Output voltage±15 Vdc
    Output current at full load±34 mA
    Output power0.51 W
    Efficiency, minimum77 %
    Efficiency, typical80 %
    Capacitive load, maximum220 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    The Figures Explained

    The module runs from a fixed input and produces ±V with no external parts. The isolation option in the part number selects standard or higher isolation voltage, which is the difference between the R and H suffixes.

    At 0.51 W out and 80 % typical efficiency the module dissipates about 0.13 W. That is the number the thermal design has to carry, not the output power.

    Positioning in the Range

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products