Eaton EPM6052V-15R-067SR Dual Output Isolated Converter
Eaton EPM6052V-15R-067SR Dual Output Isolated Converter

Eaton EPM6052V-15R-067SR Dual Output Isolated Converter

Share
EPM6052V-15R-067SR: Isolated DC-DC Converter, 5 V input, 15 V output, 67 mA, 1.01 W, 85 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6052V-15R-067SR Dual Output Isolated Converter

    EPM6052V-15R-067SR at a glance: Isolated DC-DC Converter, 5 V input, 15 V output, 67 mA, 1.01 W, 85 % typical efficiency.

    Specification Table

    ParameterValue
    Orderable part numberEPM6052V-15R-067SR
    Input voltage range5 Vdc
    Output voltage15 Vdc
    Output current at full load67 mA
    Output power1.01 W
    Efficiency, minimum82 %
    Efficiency, typical85 %
    Capacitive load, maximum220 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    What the Numbers Mean

    Dual-output isolated modules feed op-amp rails and gate drivers, where the positive and negative rails are rarely loaded equally. The data sheet gives cross regulation as a percentage, and that is the number that decides whether the negative rail sags under a single-sided load.

    At 1.005 W out and 85 % typical efficiency the module dissipates about 0.18 W. That is the number the thermal design has to carry, not the output power.

    Where This Series Fits

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    Is the total power 1 W per rail or in total?
    In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd