EPM6052V-3R3-303SR: Isolated DC-DC Converter, 5 V input, 3.3 V output, 303 mA, 1 W, 74 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6052V-3R3-303SR 1 W Dual Output DC-DC Converter

    EPM6052V-3R3-303SR at a glance: Isolated DC-DC Converter, 5 V input, 3.3 V output, 303 mA, 1 W, 74 % typical efficiency.

    Key Specifications

    ParameterValue
    Orderable part numberEPM6052V-3R3-303SR
    Input voltage range5 Vdc
    Output voltage3.3 Vdc
    Output current at full load303 mA
    Output power1 W
    Efficiency, minimum71 %
    Efficiency, typical74 %
    Capacitive load, maximum1500 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    Reading the Data Sheet

    The module runs from a fixed input and produces ±V with no external parts. The isolation option in the part number selects standard or higher isolation voltage, which is the difference between the R and H suffixes.

    At 0.9999 W out and 74 % typical efficiency the module dissipates about 0.35 W. That is the number the thermal design has to carry, not the output power.

    What This Family Is For

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    How good is the negative rail?
    Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.

    How good is the negative rail?
    Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.