| Parameter | Value |
|---|---|
| Orderable part number | EPM6121V-15R-067SH |
| Input voltage range | 12 Vdc |
| Output voltage | 15 Vdc |
| Output current at full load | 67 mA |
| Output power | 1.01 W |
| Efficiency, minimum | 78 % |
| Efficiency, typical | 81 % |
| Capacitive load, maximum | 220 uF |
| Isolation voltage | 1 kVdc |
| Isolation option | H = higher isolation voltage |
| Package | SIP |
| Operating temperature | -40 °C to +90 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1162 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1162.
Isolated modules like this appear wherever a signal has to cross a barrier: RS-485 transceivers, gate drivers, medical front ends, current shunt amplifiers. The 1 W rating is the continuous output; the input current at no load is a separate line in the data sheet.
At 1.005 W out and 81 % typical efficiency the module dissipates about 0.24 W. That is the number the thermal design has to carry, not the output power.
The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.
Why is the no-load input current specified?
Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.
Why is the no-load input current specified?
Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.
What does the isolation voltage mean in practice?
It is the test voltage the barrier withstands, not a continuous working voltage. For reinforced insulation you also need the creepage on the board, which the module cannot provide on its own.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd