EPM6121V-3R3-303SR: Isolated DC-DC Converter, 12 V input, 3.3 V output, 303 mA, 1 W, 79 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6121V-3R3-303SR 1 W Isolated DC-DC Converter 12Vin

    EPM6121V-3R3-303SR at a glance: Isolated DC-DC Converter, 12 V input, 3.3 V output, 303 mA, 1 W, 79 % typical efficiency.

    Key Specifications

    ParameterValue
    Orderable part numberEPM6121V-3R3-303SR
    Input voltage range12 Vdc
    Output voltage3.3 Vdc
    Output current at full load303 mA
    Output power1 W
    Efficiency, minimum76 %
    Efficiency, typical79 %
    Capacitive load, maximum1500 uF
    Isolation voltage1 kVdc
    Isolation optionR = standard isolation
    PackageSIP
    Operating temperature-40 °C to +90 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1162

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1162.

    The Figures Explained

    Isolated modules like this appear wherever a signal has to cross a barrier: RS-485 transceivers, gate drivers, medical front ends, current shunt amplifiers. The 1 W rating is the continuous output; the input current at no load is a separate line in the data sheet.

    At 0.9999 W out and 79 % typical efficiency the module dissipates about 0.27 W. That is the number the thermal design has to carry, not the output power.

    Positioning in the Range

    The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.

    • The isolation barrier is only as good as the board creepage around it. Check the pad spacing, not just the module rating.

    Frequently Asked Questions

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.

    Does it need external capacitors?
    The data sheet recommends input and output capacitors to meet the ripple figure. The module runs without them, but not to specification.

    Can the output be paralleled?
    Not directly. Two isolated modules will not share current without droop sharing or a series resistor, because their output voltages differ by the tolerance band.