Eaton EPM6122V-05R-100DR 5V Isolated DC-DC Converter
Eaton EPM6122V-05R-100DR 5V Isolated DC-DC Converter

Eaton EPM6122V-05R-100DR 5V Isolated DC-DC Converter

Share
EPM6122V-05R-100DR: Isolated DC-DC Converter, 12 V input, ±5 V output, ±100 mA, 0.5 W, 76 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6122V-05R-100DR 5V Isolated DC-DC Converter

    EPM6122V-05R-100DR at a glance: Isolated DC-DC Converter, 12 V input, ±5 V output, ±100 mA, 0.5 W, 76 % typical efficiency.

    Specification Table

    ParameterValue
    Orderable part numberEPM6122V-05R-100DR
    Input voltage range12 Vdc
    Output voltage±5 Vdc
    Output current at full load±100 mA
    Output power0.5 W
    Efficiency, minimum73 %
    Efficiency, typical76 %
    Capacitive load, maximum470 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    How to Read These Ratings

    A one-watt isolated module with two output rails: ±3.3, ±5, ±12 or ±15 V from a 5, 12 or 24 V input. The two rails are regulated against each other only loosely, so the cross-regulation figure matters when the load is asymmetric.

    At 0.5 W out and 76 % typical efficiency the module dissipates about 0.16 W. That is the number the thermal design has to carry, not the output power.

    Series Positioning

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    Is the total power 1 W per rail or in total?
    In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.

    Is the total power 1 W per rail or in total?
    In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.

    How good is the negative rail?
    Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd