
| Parameter | Value |
|---|---|
| Orderable part number | EPM6122V-12R-042DR |
| Input voltage range | 12 Vdc |
| Output voltage | ±12 Vdc |
| Output current at full load | ±42 mA |
| Output power | 0.5 W |
| Efficiency, minimum | 77 % |
| Efficiency, typical | 80 % |
| Capacitive load, maximum | 220 uF |
| Isolation voltage | 3 kVdc |
| Package | SIP |
| Operating temperature | -40 °C to +100 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1163 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1163.
This is the dual-output version of the standard 1 W isolated module: same pin pitch, same isolation barrier, two rails out. The output current is quoted per rail, and the total still has to stay inside the watt rating.
At 0.504 W out and 80 % typical efficiency the module dissipates about 0.13 W. That is the number the thermal design has to carry, not the output power.
The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.
Is the total power 1 W per rail or in total?
In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.
How good is the negative rail?
Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.
What is the difference between the R and H suffix?
The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd