Eaton EPM6122V-15R-067SR Dual Output Isolated Converter
Eaton EPM6122V-15R-067SR Dual Output Isolated Converter

Eaton EPM6122V-15R-067SR Dual Output Isolated Converter

Share
EPM6122V-15R-067SR: Isolated DC-DC Converter, 12 V input, 15 V output, 67 mA, 1.01 W, 81 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6122V-15R-067SR Dual Output Isolated Converter

    EPM6122V-15R-067SR at a glance: Isolated DC-DC Converter, 12 V input, 15 V output, 67 mA, 1.01 W, 81 % typical efficiency.

    Key Specifications

    ParameterValue
    Orderable part numberEPM6122V-15R-067SR
    Input voltage range12 Vdc
    Output voltage15 Vdc
    Output current at full load67 mA
    Output power1.01 W
    Efficiency, minimum78 %
    Efficiency, typical81 %
    Capacitive load, maximum220 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    What the Numbers Mean

    A one-watt isolated module with two output rails: ±3.3, ±5, ±12 or ±15 V from a 5, 12 or 24 V input. The two rails are regulated against each other only loosely, so the cross-regulation figure matters when the load is asymmetric.

    At 1.005 W out and 81 % typical efficiency the module dissipates about 0.24 W. That is the number the thermal design has to carry, not the output power.

    Where This Series Fits

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    How good is the negative rail?
    Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.

    How good is the negative rail?
    Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.

    How good is the negative rail?
    Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products