Eaton EPM6241V-12R-084SR 1 W Isolated DC-DC Converter 24Vin
Eaton EPM6241V-12R-084SR 1 W Isolated DC-DC Converter 24Vin

Eaton EPM6241V-12R-084SR 1 W Isolated DC-DC Converter 24Vin

Share
EPM6241V-12R-084SR: Isolated DC-DC Converter, 24 V input, 12 V output, 84 mA, 1.01 W, 80 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6241V-12R-084SR 1 W Isolated DC-DC Converter 24Vin

    EPM6241V-12R-084SR at a glance: Isolated DC-DC Converter, 24 V input, 12 V output, 84 mA, 1.01 W, 80 % typical efficiency.

    Key Specifications

    ParameterValue
    Orderable part numberEPM6241V-12R-084SR
    Input voltage range24 Vdc
    Output voltage12 Vdc
    Output current at full load84 mA
    Output power1.01 W
    Efficiency, minimum77 %
    Efficiency, typical80 %
    Capacitive load, maximum470 uF
    Isolation voltage1 kVdc
    Isolation optionR = standard isolation
    PackageSIP
    Operating temperature-40 °C to +90 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1162

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1162.

    How to Read These Ratings

    These modules are chosen for isolation first and power second. One watt at 70 to 85 percent efficiency is not a thermal problem; the questions are the isolation voltage, the regulation across the load range and whether the output can start into a capacitive load.

    At 1.008 W out and 80 % typical efficiency the module dissipates about 0.25 W. That is the number the thermal design has to carry, not the output power.

    Positioning in the Range

    The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.

    • The isolation barrier is only as good as the board creepage around it. Check the pad spacing, not just the module rating.

    Frequently Asked Questions

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.

    Does it need external capacitors?
    The data sheet recommends input and output capacitors to meet the ripple figure. The module runs without them, but not to specification.

    Does it need external capacitors?
    The data sheet recommends input and output capacitors to meet the ripple figure. The module runs without them, but not to specification.