Eaton EPM6242V-05R-200SR 5V Isolated DC-DC Converter
Eaton EPM6242V-05R-200SR 5V Isolated DC-DC Converter

Eaton EPM6242V-05R-200SR 5V Isolated DC-DC Converter

Share
EPM6242V-05R-200SR: Isolated DC-DC Converter, 24 V input, 5 V output, 200 mA, 1 W, 79 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6242V-05R-200SR 5V Isolated DC-DC Converter

    EPM6242V-05R-200SR at a glance: Isolated DC-DC Converter, 24 V input, 5 V output, 200 mA, 1 W, 79 % typical efficiency.

    Electrical Specifications

    ParameterValue
    Orderable part numberEPM6242V-05R-200SR
    Input voltage range24 Vdc
    Output voltage5 Vdc
    Output current at full load200 mA
    Output power1 W
    Efficiency, minimum76 %
    Efficiency, typical79 %
    Capacitive load, maximum1500 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    Reading the Data Sheet

    This is the dual-output version of the standard 1 W isolated module: same pin pitch, same isolation barrier, two rails out. The output current is quoted per rail, and the total still has to stay inside the watt rating.

    At 1 W out and 79 % typical efficiency the module dissipates about 0.27 W. That is the number the thermal design has to carry, not the output power.

    Series Positioning

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    How good is the negative rail?
    Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.