EPM7121V-12R-042DH: Isolated DC-DC Converter, 12 V input, ±12 V output, ±42 mA, 0.5 W, 80 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM7121V-12R-042DH 1 W DC-DC Module, 12V Input

    EPM7121V-12R-042DH at a glance: Isolated DC-DC Converter, 12 V input, ±12 V output, ±42 mA, 0.5 W, 80 % typical efficiency.

    Specification Table

    ParameterValue
    Orderable part numberEPM7121V-12R-042DH
    Input voltage range12 Vdc
    Output voltage±12 Vdc
    Output current at full load±42 mA
    Output power0.5 W
    Efficiency, minimum77 %
    Efficiency, typical80 %
    Capacitive load, maximum220 uF
    Isolation voltage4 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1164

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1164.

    Reading the Data Sheet

    The converter is a fixed-frequency push-pull stage behind a transformer, potted into a case with the pins on a 2.54 mm grid. It needs no external components to run, which is the point: two decoupling capacitors and it works.

    At 0.504 W out and 80 % typical efficiency the module dissipates about 0.13 W. That is the number the thermal design has to carry, not the output power.

    What This Family Is For

    The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.

    • The isolation barrier is only as good as the board creepage around it. Check the pad spacing, not just the module rating.

    Frequently Asked Questions

    Can the output be paralleled?
    Not directly. Two isolated modules will not share current without droop sharing or a series resistor, because their output voltages differ by the tolerance band.

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.