| Parameter | Value |
|---|---|
| Orderable part number | EPM7121V-12R-084SH |
| Input voltage range | 12 Vdc |
| Output voltage | 12 Vdc |
| Output current at full load | 84 mA |
| Output power | 1.01 W |
| Efficiency, minimum | 77 % |
| Efficiency, typical | 80 % |
| Capacitive load, maximum | 470 uF |
| Isolation voltage | 4 kVdc |
| Package | SIP |
| Operating temperature | -40 °C to +100 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1164 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1164.
A one-watt isolated DC-DC module in a SIP or DIP footprint: 5, 12 or 24 V in, single or dual output out, with galvanic isolation between the two sides. It is the part that breaks a ground loop or floats a gate driver supply when a full converter would be overkill.
At 1.008 W out and 80 % typical efficiency the module dissipates about 0.25 W. That is the number the thermal design has to carry, not the output power.
The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.
Can the output be paralleled?
Not directly. Two isolated modules will not share current without droop sharing or a series resistor, because their output voltages differ by the tolerance band.
Does it need external capacitors?
The data sheet recommends input and output capacitors to meet the ripple figure. The module runs without them, but not to specification.
Why is the no-load input current specified?
Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd