Eaton EPM7241V-12R-042DH 1 W DC-DC Module, 24V Input
Eaton EPM7241V-12R-042DH 1 W DC-DC Module, 24V Input

Eaton EPM7241V-12R-042DH 1 W DC-DC Module, 24V Input

Share
EPM7241V-12R-042DH: Isolated DC-DC Converter, 24 V input, ±12 V output, ±42 mA, 0.5 W, 80 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM7241V-12R-042DH 1 W DC-DC Module, 24V Input

    EPM7241V-12R-042DH at a glance: Isolated DC-DC Converter, 24 V input, ±12 V output, ±42 mA, 0.5 W, 80 % typical efficiency.

    Key Specifications

    ParameterValue
    Orderable part numberEPM7241V-12R-042DH
    Input voltage range24 Vdc
    Output voltage±12 Vdc
    Output current at full load±42 mA
    Output power0.5 W
    Efficiency, minimum77 %
    Efficiency, typical80 %
    Capacitive load, maximum220 uF
    Isolation voltage4 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1164

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1164.

    Reading the Data Sheet

    Isolated modules like this appear wherever a signal has to cross a barrier: RS-485 transceivers, gate drivers, medical front ends, current shunt amplifiers. The 1 W rating is the continuous output; the input current at no load is a separate line in the data sheet.

    At 0.504 W out and 80 % typical efficiency the module dissipates about 0.13 W. That is the number the thermal design has to carry, not the output power.

    What This Family Is For

    The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.

    • The isolation barrier is only as good as the board creepage around it. Check the pad spacing, not just the module rating.

    Frequently Asked Questions

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.

    Does it need external capacitors?
    The data sheet recommends input and output capacitors to meet the ripple figure. The module runs without them, but not to specification.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products