| Parameter | Value |
|---|---|
| Orderable part number | EREC0102FL |
| Repetitive peak reverse voltage (VRRM) | 200 V |
| Maximum RMS voltage (VRMS) | 140 V |
| Maximum DC blocking voltage (VDC) | 200 V |
| Average forward current (IF(AV)) | 1 A at TA= +85 °C |
| Peak forward surge current (IFSM) | 35 A, 8.3 ms half sine |
| Forward voltage (VF) | 0.95 V max, @IF=1 A Tj=25 °C |
| Reverse current at VRRM, 25 °C | 1 uA max |
| Reverse recovery time (trr) | 25 ns max |
| Reverse recovery charge (Qrr) | 17 nC typ |
| Peak reverse recovery current (IRM) | 1.7 A typ |
| Thermal resistance, junction to ambient | 170 °C/W |
| Operating junction and storage temperature | -55 °C to +150 °C |
| Package | SOD-123FL |
| Mounting | Surface mount |
| Weight | 0.0144 g typical |
| Recovery class | Hyperfast |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1289 |
Rating conditions (ambient or case temperature, test current, dI/dt) are
as printed in Eaton Technical Data ELX1289; the values above are taken from the
table for this part number, not from a family summary.
These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.
1 A through a 0.95 V drop is 0.95 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.
Against 170 °C/W the same 0.95 W lifts the junction by about 162 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.
The 200 V repetitive rating comes with a 140 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.
The surge rating is 35 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.
The recovery waveform matters as much as its duration. Soft recovery means the current falls back to zero without a sharp snap, which keeps the voltage spike across the parasitic inductance of the loop low. A hard recovery of the same trr can ring harder.
Keep the commutating loop small. The reverse recovery current falls out of the diode into the switch that turned it off, and that current times the loop inductance is the voltage overshoot the switch has to survive. A few centimetres of loop is enough to double the spike.
Does a faster recovery always mean less loss?
No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.
Can these be paralleled?
Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.
What does soft recovery actually mean?
The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.