EREC0202SA: 200 V, 2 A hyperfast recovery rectifier, 1 V forward drop, 25 ns trr, DO-214AC.
    • Product Details
    • Download

    Eaton EREC0202SA 200 V 2 A Fast Recovery Diode

    EREC0202SA at a glance: hyperfast recovery rectifier, 200 V, 2 A, 1 V forward drop, 25 ns recovery, DO-214AC.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEREC0202SA
    Repetitive peak reverse voltage (VRRM)200 V
    Maximum RMS voltage (VRMS)140 V
    Maximum DC blocking voltage (VDC)200 V
    Average forward current (IF(AV))2 A at TA=85 °C
    Peak forward surge current (IFSM)40 A, 8.3 ms half sine
    Forward voltage (VF)1 V max, IF=1 A, Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)25 ns max
    Thermal resistance, junction to ambient100 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageDO-214AC
    MountingSurface mount
    Weight0.0673 g typical
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1290

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1290; the values above are taken from the
    table for this part number, not from a family summary.

    Reading the Data Sheet

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    2 A through a 1 V drop is 2 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 100 °C/W the same 2 W lifts the junction by about 200 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 200 V repetitive rating comes with a 140 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 20 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    Hyperfast and superfast are relative terms. The die is a P-I-N structure with a thin drift region and lifetime control, so the stored charge that has to be swept out at turn-off is small. That is what makes the recovery time a few tens of nanoseconds instead of a few microseconds.

    Layout and Placement

    On a bridge or a PFC stage, keep the return path of each diode pair on the same layer. The recovery currents of the two halves then share a path instead of crossing the board through vias.

    • Average forward current is quoted at a case or ambient temperature. Run the part hotter and the allowable current falls faster than the linear derating curve suggests, because the forward drop rises with temperature as well.
    • Thermal resistance from junction to ambient includes the copper area named in the note under the table. Junction to case, where it is given, is the number to use with a heatsink calculation.

    Frequently Asked Questions

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.

    What package should a 600 V, 10 A design use?
    The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.