| Parameter | Value |
|---|---|
| Orderable part number | EREC0502K |
| Repetitive peak reverse voltage (VRRM) | 200 V |
| Maximum RMS voltage (VRMS) | 140 V |
| Maximum DC blocking voltage (VDC) | 200 V |
| Average forward current (IF(AV)) | 5 A at Tc = +120 °C |
| Peak forward surge current (IFSM) | 65 A, 8.3 ms half sine |
| Forward voltage (VF) | 0.95 V max, @IF=5 A Tj=25 °C |
| Reverse current at VRRM, 25 °C | 5 uA max |
| Reverse recovery time (trr) | 25 ns max |
| Thermal resistance, junction to case | 14 °C/W |
| Operating junction and storage temperature | -55 °C to +150 °C |
| Package | TO-252 |
| Mounting | Surface mount |
| Weight | 0.329 g typical |
| Recovery class | Hyperfast |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1292 |
Rating conditions (ambient or case temperature, test current, dI/dt) are
as printed in Eaton Technical Data ELX1292; the values above are taken from the
table for this part number, not from a family summary.
These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.
5 A through a 0.95 V drop is 4.75 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.
Against 14 °C/W the same 4.75 W lifts the junction by about 66 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.
The 200 V repetitive rating comes with a 140 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.
The surge rating is 13 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.
Forward voltage and recovery time trade against each other in the design of the die. The family is offered in two recovery classes for that reason: the softer, faster part costs a little forward drop, and the lower drop part gives some of the speed back.
Place the snubber or the clamp across the diode only after the loop has been made as short as it can be. A snubber that compensates for a bad layout burns power every cycle to fix what copper would have fixed for free.
What does soft recovery actually mean?
The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.
What package should a 600 V, 10 A design use?
The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.
How is the heatsink sized?
Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.