Eaton EREC0506CL 600 V 5 A Fast Recovery Diode
Eaton EREC0506CL 600 V 5 A Fast Recovery Diode

Eaton EREC0506CL 600 V 5 A Fast Recovery Diode

Share
EREC0506CL: 600 V, 5 A hyperfast recovery rectifier, 3.3 V forward drop, 11 ns trr, TO-220C-2L.
    • Product Details
    • Download

    Eaton EREC0506CL 600 V 5 A Fast Recovery Diode

    EREC0506CL at a glance: hyperfast recovery rectifier, 600 V, 5 A, 3.3 V forward drop, 11 ns recovery, TO-220C-2L.

    Electrical Specifications

    ParameterValue
    Orderable part numberEREC0506CL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))5 A at Tmb≤133 °C square-wave pulse
    Peak forward surge current (IFSM)60 A, 8.3 ms half sine
    Forward voltage (VF)3.3 V max (typ 2.5 V), IF=5A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)11 ns typ
    Reverse recovery charge (Qrr)19 nC typ
    Peak reverse recovery current (IRM)1.7 A typ
    Thermal resistance, junction to ambient60 °C/W
    Thermal resistance, junction to case3.5 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220C-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1293

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1293; the values above are taken from the
    table for this part number, not from a family summary.

    The Figures Explained

    Forward voltage and recovery time trade against each other in the design of the die. The family is offered in two recovery classes for that reason: the softer, faster part costs a little forward drop, and the lower drop part gives some of the speed back.

    5 A through a 3.3 V drop is 16.5 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 60 °C/W the same 16.5 W lifts the junction by about 990 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 12 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.

    Placement in the Circuit

    Place the snubber or the clamp across the diode only after the loop has been made as short as it can be. A snubber that compensates for a bad layout burns power every cycle to fix what copper would have fixed for free.

    • The surge current rating is a single half sinewave. Repetitive inrush, such as a capacitive load charging every time the supply is switched on, heats the die far more than one cold start.
    • Thermal resistance from junction to ambient includes the copper area named in the note under the table. Junction to case, where it is given, is the number to use with a heatsink calculation.

    Frequently Asked Questions

    How is the heatsink sized?
    Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.

    Is the surge rating a repetitive rating?
    It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.