    EREC0506FPL at a glance: hyperfast recovery rectifier, 600 V, 5 A, 3.3 V forward drop, 11 ns recovery, TO-220FP-2L.

    Specification Table

    ParameterValue
    Orderable part numberEREC0506FPL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))5 A at Th ≤97 °C
    Peak forward surge current (IFSM)60 A, 8.3 ms half sine
    Forward voltage (VF)3.3 V max (typ 2.5 V), IF=5 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)11 ns typ
    Reverse recovery charge (Qrr)19 nC typ
    Peak reverse recovery current (IRM)1.7 A typ
    Thermal resistance, junction to ambient55 °C/W
    Thermal resistance, junction to case6.5 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220FP-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1294

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1294; the values above are taken from the
    table for this part number, not from a family summary.

    How to Read These Ratings

    Hyperfast and superfast are relative terms. The die is a P-I-N structure with a thin drift region and lifetime control, so the stored charge that has to be swept out at turn-off is small. That is what makes the recovery time a few tens of nanoseconds instead of a few microseconds.

    5 A through a 3.3 V drop is 16.5 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 55 °C/W the same 16.5 W lifts the junction by about 908 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 12 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    Board Layout

    Bolt or solder the tab to copper that spreads heat, not just to the pad the footprint asks for. The junction-to-ambient figure assumes a specific copper area, and a smaller island quietly derates the part.

    • The reverse voltage rating is a peak repetitive figure at the specified temperature. A mains-fed bridge on 230 V RMS sees 325 V peaks plus the surge margin, so a 400 V part is the minimum and 600 V is the usual choice.
    • The plastic package is UL 94V-0 rated and the terminals are tin plated. Wave or reflow soldering limits are in the data sheet; the peak body temperature is the constraint, not the dwell time at a lower temperature.

    Frequently Asked Questions

    What package should a 600 V, 10 A design use?
    The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.

    What does soft recovery actually mean?
    The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.