EREC0806E: 600 V, 8 A hyperfast recovery rectifier, 3.4 V forward drop, 18 ns trr, TO-263.
    • Product Details
    • Download

    Eaton EREC0806E Hyperfast Recovery Rectifier 18 ns

    EREC0806E at a glance: hyperfast recovery rectifier, 600 V, 8 A, 3.4 V forward drop, 18 ns recovery, TO-263.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEREC0806E
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))8 A at Tmb ≤130 °C
    Peak forward surge current (IFSM)90 A, 8.3 ms half sine
    Forward voltage (VF)3.4 V max, IF=8 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)12 ns typ / 18 ns max
    Reverse recovery charge (Qrr)17 nC typ
    Peak reverse recovery current (IRM)2.2 A typ
    Thermal resistance, junction to ambient60 °C/W
    Thermal resistance, junction to case2.5 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-263
    MountingSurface mount
    Weight1.55 g typical
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1296

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1296; the values above are taken from the
    table for this part number, not from a family summary.

    Reading the Data Sheet

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    8 A through a 3.4 V drop is 27.2 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 60 °C/W the same 27.2 W lifts the junction by about 1632 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 11 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    Layout and Placement

    Bolt or solder the tab to copper that spreads heat, not just to the pad the footprint asks for. The junction-to-ambient figure assumes a specific copper area, and a smaller island quietly derates the part.

    • The reverse voltage rating is a peak repetitive figure at the specified temperature. A mains-fed bridge on 230 V RMS sees 325 V peaks plus the surge margin, so a 400 V part is the minimum and 600 V is the usual choice.
    • Reverse recovery charge is the integral of the recovery current. It is the figure that turns into switching loss in the counterpart switch, and it scales with forward current, not with voltage.

    Frequently Asked Questions

    What does soft recovery actually mean?
    The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.