Eaton EREC0806FPL 600 V 8 A Hyperfast Rectifier
Eaton EREC0806FPL 600 V 8 A Hyperfast Rectifier

Eaton EREC0806FPL 600 V 8 A Hyperfast Rectifier

Share
EREC0806FPL: 600 V, 8 A hyperfast recovery rectifier, 3.4 V forward drop, 18 ns trr, TO-220FP-2L.
    • Product Details
    • Download

    Eaton EREC0806FPL 600 V 8 A Hyperfast Rectifier

    EREC0806FPL at a glance: hyperfast recovery rectifier, 600 V, 8 A, 3.4 V forward drop, 18 ns recovery, TO-220FP-2L.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEREC0806FPL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))8 A at Th ≤75 °C
    Peak forward surge current (IFSM)90 A, 8.3 ms half sine
    Forward voltage (VF)3.4 V max, IF=8 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)12 ns typ / 18 ns max
    Reverse recovery charge (Qrr)17 nC typ
    Peak reverse recovery current (IRM)2.2 A typ
    Thermal resistance, junction to ambient60 °C/W
    Thermal resistance, junction to case5.5 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220FP-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1297

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1297; the values above are taken from the
    table for this part number, not from a family summary.

    Reading the Data Sheet

    These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.

    8 A through a 3.4 V drop is 27.2 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 60 °C/W the same 27.2 W lifts the junction by about 1632 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 11 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    Layout and Placement

    Bolt or solder the tab to copper that spreads heat, not just to the pad the footprint asks for. The junction-to-ambient figure assumes a specific copper area, and a smaller island quietly derates the part.

    • Recovery time is quoted at a specific dI/dt and forward current. Change the commutation rate and the number moves; a part measured at 100 A/us can behave differently at 500 A/us.
    • Reverse recovery charge is the integral of the recovery current. It is the figure that turns into switching loss in the counterpart switch, and it scales with forward current, not with voltage.

    Frequently Asked Questions

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.

    How is the heatsink sized?
    Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.