EREC1002FPC: 200 V, 10 A hyperfast recovery rectifier, 1.1 V forward drop, 25 ns trr, TO-220FP.
    • Product Details
    • Download

    Eaton EREC1002FPC 200 V 10 A Fast Recovery Diode

    EREC1002FPC at a glance: hyperfast recovery rectifier, 200 V, 10 A, 1.1 V forward drop, 25 ns recovery, TO-220FP.

    Specification Table

    ParameterValue
    Orderable part numberEREC1002FPC
    Repetitive peak reverse voltage (VRRM)200 V
    Maximum RMS voltage (VRMS)140 V
    Maximum DC blocking voltage (VDC)200 V
    Average forward current (IF(AV))10 A at Th≤ 92 °C,
    Peak forward surge current (IFSM)50 A, 8.3 ms half sine
    Forward voltage (VF)1.1 V max (typ 0.95 V), @IF=5A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)25 ns max
    Thermal resistance, junction to ambient55 °C/W
    Thermal resistance, junction to case5.7 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220FP
    MountingThrough-hole
    Weight2.07 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1335

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1335; the values above are taken from the
    table for this part number, not from a family summary.

    How to Read These Ratings

    Forward voltage and recovery time trade against each other in the design of the die. The family is offered in two recovery classes for that reason: the softer, faster part costs a little forward drop, and the lower drop part gives some of the speed back.

    10 A through a 1.1 V drop is 11 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 55 °C/W the same 11 W lifts the junction by about 605 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 200 V repetitive rating comes with a 140 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 5 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    The recovery waveform matters as much as its duration. Soft recovery means the current falls back to zero without a sharp snap, which keeps the voltage spike across the parasitic inductance of the loop low. A hard recovery of the same trr can ring harder.

    Board Layout

    Keep the commutating loop small. The reverse recovery current falls out of the diode into the switch that turned it off, and that current times the loop inductance is the voltage overshoot the switch has to survive. A few centimetres of loop is enough to double the spike.

    • The surge current rating is a single half sinewave. Repetitive inrush, such as a capacitive load charging every time the supply is switched on, heats the die far more than one cold start.
    • Reverse recovery charge is the integral of the recovery current. It is the figure that turns into switching loss in the counterpart switch, and it scales with forward current, not with voltage.

    Frequently Asked Questions

    Is the surge rating a repetitive rating?
    It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.