Eaton EREC1006CL 600 V 10 A Hyperfast Rectifier
Eaton EREC1006CL 600 V 10 A Hyperfast Rectifier

Eaton EREC1006CL 600 V 10 A Hyperfast Rectifier

Share
EREC1006CL: 600 V, 10 A hyperfast recovery rectifier, 3.2 V forward drop, 18 ns trr, TO-220C-2L.
    • Product Details
    • Download

    Eaton EREC1006CL 600 V 10 A Hyperfast Rectifier

    EREC1006CL at a glance: hyperfast recovery rectifier, 600 V, 10 A, 3.2 V forward drop, 18 ns recovery, TO-220C-2L.

    Key Specifications

    ParameterValue
    Orderable part numberEREC1006CL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))10 A at Tmb ≤127 °C.
    Peak forward surge current (IFSM)120 A, 8.3 ms half sine
    Forward voltage (VF)3.2 V max (typ 2.5 V), @IF=10 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)12 ns typ / 18 ns max
    Reverse recovery charge (Qrr)26 nC typ
    Peak reverse recovery current (IRM)2 A typ
    Thermal resistance, junction to ambient60 °C/W
    Thermal resistance, junction to case2 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220C-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1337

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1337; the values above are taken from the
    table for this part number, not from a family summary.

    What the Numbers Mean

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    10 A through a 3.2 V drop is 32 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 60 °C/W the same 32 W lifts the junction by about 1920 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 12 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.

    Where It Goes on the Board

    Place the snubber or the clamp across the diode only after the loop has been made as short as it can be. A snubber that compensates for a bad layout burns power every cycle to fix what copper would have fixed for free.

    • The reverse voltage rating is a peak repetitive figure at the specified temperature. A mains-fed bridge on 230 V RMS sees 325 V peaks plus the surge margin, so a 400 V part is the minimum and 600 V is the usual choice.
    • Thermal resistance from junction to ambient includes the copper area named in the note under the table. Junction to case, where it is given, is the number to use with a heatsink calculation.

    Frequently Asked Questions

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.

    Is the surge rating a repetitive rating?
    It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.