Eaton EREC1006FPL 600 V 10 A Fast Recovery Diode
Eaton EREC1006FPL 600 V 10 A Fast Recovery Diode

Eaton EREC1006FPL 600 V 10 A Fast Recovery Diode

Share
EREC1006FPL: 600 V, 10 A hyperfast recovery rectifier, 3.2 V forward drop, 18 ns trr, TO-220FP-2L.
    • Product Details
    • Download

    Eaton EREC1006FPL 600 V 10 A Fast Recovery Diode

    EREC1006FPL at a glance: hyperfast recovery rectifier, 600 V, 10 A, 3.2 V forward drop, 18 ns recovery, TO-220FP-2L.

    Specification Table

    ParameterValue
    Orderable part numberEREC1006FPL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))10 A at Th ≤61 °C
    Peak forward surge current (IFSM)120 A, 8.3 ms half sine
    Forward voltage (VF)3.2 V max (typ 2.5 V), @IF=10 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)12 ns typ / 18 ns max
    Reverse recovery charge (Qrr)26 nC typ
    Peak reverse recovery current (IRM)2 A typ
    Thermal resistance, junction to ambient55 °C/W
    Thermal resistance, junction to case4.8 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220FP-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1338

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1338; the values above are taken from the
    table for this part number, not from a family summary.

    How to Read These Ratings

    Hyperfast and superfast are relative terms. The die is a P-I-N structure with a thin drift region and lifetime control, so the stored charge that has to be swept out at turn-off is small. That is what makes the recovery time a few tens of nanoseconds instead of a few microseconds.

    10 A through a 3.2 V drop is 32 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 55 °C/W the same 32 W lifts the junction by about 1760 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 12 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.

    Board Layout

    Keep the commutating loop small. The reverse recovery current falls out of the diode into the switch that turned it off, and that current times the loop inductance is the voltage overshoot the switch has to survive. A few centimetres of loop is enough to double the spike.

    • The reverse voltage rating is a peak repetitive figure at the specified temperature. A mains-fed bridge on 230 V RMS sees 325 V peaks plus the surge margin, so a 400 V part is the minimum and 600 V is the usual choice.
    • Thermal resistance from junction to ambient includes the copper area named in the note under the table. Junction to case, where it is given, is the number to use with a heatsink calculation.

    Frequently Asked Questions

    What package should a 600 V, 10 A design use?
    The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.

    How much voltage margin should the diode have?
    The repetitive peak reverse voltage should clear the worst-case peak on the line with margin for regulation and surge. On a 230 V mains input that means 600 V is the practical choice rather than 400 V, because the peak already sits at 325 V before any transient.

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.