Eaton EREC1506E 600 V 15 A Fast Recovery Diode
Eaton EREC1506E 600 V 15 A Fast Recovery Diode

Eaton EREC1506E 600 V 15 A Fast Recovery Diode

Share
EREC1506E: 600 V, 15 A hyperfast recovery rectifier, 3.2 V forward drop, 18 ns trr, TO-263.
    • Product Details
    • Download

    Eaton EREC1506E 600 V 15 A Fast Recovery Diode

    EREC1506E at a glance: hyperfast recovery rectifier, 600 V, 15 A, 3.2 V forward drop, 18 ns recovery, TO-263.

    Key Specifications

    ParameterValue
    Orderable part numberEREC1506E
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))15 A at TC=125 °C
    Peak forward surge current (IFSM)180 A, 8.3 ms half sine
    Forward voltage (VF)3.2 V max (typ 2.6 V), IF=15 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)13 ns typ / 18 ns max
    Reverse recovery charge (Qrr)30 nC typ
    Peak reverse recovery current (IRM)2.1 A typ
    Thermal resistance, junction to case1.7 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-263
    MountingSurface mount
    Weight1.55 g typical
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1341

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1341; the values above are taken from the
    table for this part number, not from a family summary.

    What the Numbers Mean

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    15 A through a 3.2 V drop is 48 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 1.7 °C/W the same 48 W lifts the junction by about 82 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 12 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    Where It Goes on the Board

    Keep the commutating loop small. The reverse recovery current falls out of the diode into the switch that turned it off, and that current times the loop inductance is the voltage overshoot the switch has to survive. A few centimetres of loop is enough to double the spike.

    • The surge current rating is a single half sinewave. Repetitive inrush, such as a capacitive load charging every time the supply is switched on, heats the die far more than one cold start.
    • The forward voltage is specified at a pulse or a defined junction temperature. It has a negative temperature coefficient at low current and a positive one at high current, which is why paralleling needs care.

    Frequently Asked Questions

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.

    How much voltage margin should the diode have?
    The repetitive peak reverse voltage should clear the worst-case peak on the line with margin for regulation and surge. On a 230 V mains input that means 600 V is the practical choice rather than 400 V, because the peak already sits at 325 V before any transient.

    What package should a 600 V, 10 A design use?
    The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.