Eaton EREC2006AL Hyperfast Recovery Rectifier 20 ns
Eaton EREC2006AL Hyperfast Recovery Rectifier 20 ns

Eaton EREC2006AL Hyperfast Recovery Rectifier 20 ns

Share
EREC2006AL: 600 V, 20 A hyperfast recovery rectifier, 2.9 V forward drop, 20 ns trr, TO-220A-2L.
    • Product Details
    • Download

    Eaton EREC2006AL Hyperfast Recovery Rectifier 20 ns

    EREC2006AL at a glance: hyperfast recovery rectifier, 600 V, 20 A, 2.9 V forward drop, 20 ns recovery, TO-220A-2L.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEREC2006AL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))20 A at Tmb =120 °C
    Peak forward surge current (IFSM)200 A, 8.3 ms half sine
    Forward voltage (VF)2.9 V max (typ 2 V), IF=20 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)16 ns typ / 20 ns max
    Reverse recovery charge (Qrr)47 nC typ
    Peak reverse recovery current (IRM)2.8 A typ
    Thermal resistance, junction to ambient60 °C/W
    Thermal resistance, junction to case2.1 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220A-2L
    MountingThrough-hole
    Weight2.1 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1345

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1345; the values above are taken from the
    table for this part number, not from a family summary.

    Reading the Data Sheet

    These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.

    20 A through a 2.9 V drop is 58 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 60 °C/W the same 58 W lifts the junction by about 3480 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 10 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    Layout and Placement

    Bolt or solder the tab to copper that spreads heat, not just to the pad the footprint asks for. The junction-to-ambient figure assumes a specific copper area, and a smaller island quietly derates the part.

    • Average forward current is quoted at a case or ambient temperature. Run the part hotter and the allowable current falls faster than the linear derating curve suggests, because the forward drop rises with temperature as well.
    • The plastic package is UL 94V-0 rated and the terminals are tin plated. Wave or reflow soldering limits are in the data sheet; the peak body temperature is the constraint, not the dwell time at a lower temperature.

    Frequently Asked Questions

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.

    Is the surge rating a repetitive rating?
    It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.