Eaton EREC2006CL 600 V 20 A Hyperfast Rectifier
Eaton EREC2006CL 600 V 20 A Hyperfast Rectifier

Eaton EREC2006CL 600 V 20 A Hyperfast Rectifier

Share
EREC2006CL: 600 V, 20 A hyperfast recovery rectifier, 2.9 V forward drop, 20 ns trr, TO-220C-2L.
    • Product Details
    • Download

    Eaton EREC2006CL 600 V 20 A Hyperfast Rectifier

    EREC2006CL at a glance: hyperfast recovery rectifier, 600 V, 20 A, 2.9 V forward drop, 20 ns recovery, TO-220C-2L.

    Electrical Specifications

    ParameterValue
    Orderable part numberEREC2006CL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))20 A at Tmb =120 °C
    Peak forward surge current (IFSM)200 A, 8.3 ms half sine
    Forward voltage (VF)2.9 V max (typ 2 V), IF=20 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)16 ns typ / 20 ns max
    Reverse recovery charge (Qrr)47 nC typ
    Peak reverse recovery current (IRM)2.8 A typ
    Thermal resistance, junction to ambient60 °C/W
    Thermal resistance, junction to case1.2 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220C-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1346

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1346; the values above are taken from the
    table for this part number, not from a family summary.

    The Figures Explained

    The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.

    20 A through a 2.9 V drop is 58 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 60 °C/W the same 58 W lifts the junction by about 3480 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 10 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.

    Placement in the Circuit

    On a bridge or a PFC stage, keep the return path of each diode pair on the same layer. The recovery currents of the two halves then share a path instead of crossing the board through vias.

    • The surge current rating is a single half sinewave. Repetitive inrush, such as a capacitive load charging every time the supply is switched on, heats the die far more than one cold start.
    • The forward voltage is specified at a pulse or a defined junction temperature. It has a negative temperature coefficient at low current and a positive one at high current, which is why paralleling needs care.

    Frequently Asked Questions

    How is the heatsink sized?
    Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.