Eaton EREC3006AL Hyperfast Recovery Rectifier 35 ns
Eaton EREC3006AL Hyperfast Recovery Rectifier 35 ns

Eaton EREC3006AL Hyperfast Recovery Rectifier 35 ns

Share
EREC3006AL: 600 V, 30 A hyperfast recovery rectifier, 2.75 V forward drop, 35 ns trr, TO-220A-2L.
    • Product Details
    • Download

    Eaton EREC3006AL Hyperfast Recovery Rectifier 35 ns

    EREC3006AL at a glance: hyperfast recovery rectifier, 600 V, 30 A, 2.75 V forward drop, 35 ns recovery, TO-220A-2L.

    Specification Table

    ParameterValue
    Orderable part numberEREC3006AL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))30 A at Tmb ≤90 °C
    Peak forward surge current (IFSM)200 A, 8.3 ms half sine
    Forward voltage (VF)2.75 V max (typ 2 V), IF=30 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Reverse recovery charge (Qrr)50 nC typ
    Peak reverse recovery current (IRM)3.5 A typ
    Thermal resistance, junction to ambient60 °C/W
    Thermal resistance, junction to case2.1 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220A-2L
    MountingThrough-hole
    Weight2.1 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1348

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1348; the values above are taken from the
    table for this part number, not from a family summary.

    How to Read These Ratings

    The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.

    30 A through a 2.75 V drop is 82.5 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 60 °C/W the same 82.5 W lifts the junction by about 4950 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 7 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.

    Board Layout

    On a bridge or a PFC stage, keep the return path of each diode pair on the same layer. The recovery currents of the two halves then share a path instead of crossing the board through vias.

    • The reverse voltage rating is a peak repetitive figure at the specified temperature. A mains-fed bridge on 230 V RMS sees 325 V peaks plus the surge margin, so a 400 V part is the minimum and 600 V is the usual choice.
    • The plastic package is UL 94V-0 rated and the terminals are tin plated. Wave or reflow soldering limits are in the data sheet; the peak body temperature is the constraint, not the dwell time at a lower temperature.

    Frequently Asked Questions

    What package should a 600 V, 10 A design use?
    The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.

    How is the heatsink sized?
    Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.