Eaton EREC3006CL 600 V 30 A Hyperfast Rectifier
Eaton EREC3006CL 600 V 30 A Hyperfast Rectifier

Eaton EREC3006CL 600 V 30 A Hyperfast Rectifier

Share
EREC3006CL: 600 V, 30 A hyperfast recovery rectifier, 2.75 V forward drop, 35 ns trr, TO-220C-2L.
    • Product Details
    • Download

    Eaton EREC3006CL 600 V 30 A Hyperfast Rectifier

    EREC3006CL at a glance: hyperfast recovery rectifier, 600 V, 30 A, 2.75 V forward drop, 35 ns recovery, TO-220C-2L.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEREC3006CL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))30 A at Tmb ≤104 °C
    Peak forward surge current (IFSM)200 A, 8.3 ms half sine
    Forward voltage (VF)2.75 V max (typ 2 V), IF=30 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Reverse recovery charge (Qrr)50 nC typ
    Peak reverse recovery current (IRM)3.5 A typ
    Thermal resistance, junction to ambient60 °C/W
    Thermal resistance, junction to case1.2 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220C-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1349

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1349; the values above are taken from the
    table for this part number, not from a family summary.

    Reading the Data Sheet

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    30 A through a 2.75 V drop is 82.5 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 60 °C/W the same 82.5 W lifts the junction by about 4950 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 7 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    Layout and Placement

    Place the snubber or the clamp across the diode only after the loop has been made as short as it can be. A snubber that compensates for a bad layout burns power every cycle to fix what copper would have fixed for free.

    • Recovery time is quoted at a specific dI/dt and forward current. Change the commutation rate and the number moves; a part measured at 100 A/us can behave differently at 500 A/us.
    • The plastic package is UL 94V-0 rated and the terminals are tin plated. Wave or reflow soldering limits are in the data sheet; the peak body temperature is the constraint, not the dwell time at a lower temperature.

    Frequently Asked Questions

    What does soft recovery actually mean?
    The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.

    Is the surge rating a repetitive rating?
    It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.