Eaton EREC3006TC Hyperfast Recovery Rectifier 18 ns
Eaton EREC3006TC Hyperfast Recovery Rectifier 18 ns

Eaton EREC3006TC Hyperfast Recovery Rectifier 18 ns

Share
EREC3006TC: 600 V, 30 A hyperfast recovery rectifier, 3.2 V forward drop, 18 ns trr, TO-247J.
    • Product Details
    • Download

    Eaton EREC3006TC Hyperfast Recovery Rectifier 18 ns

    EREC3006TC at a glance: hyperfast recovery rectifier, 600 V, 30 A, 3.2 V forward drop, 18 ns recovery, TO-247J.

    Key Specifications

    ParameterValue
    Orderable part numberEREC3006TC
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))30 A at Tc = 140 °C
    Peak forward surge current (IFSM)150 A, 8.3 ms half sine
    Forward voltage (VF)3.2 V max (typ 2.7 V), IF=15 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)13 ns typ / 18 ns max
    Reverse recovery charge (Qrr)30 nC typ
    Peak reverse recovery current (IRM)2.1 A typ
    Thermal resistance, junction to case1.6 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-247J
    MountingThrough-hole
    Weight6.0 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1409

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1409; the values above are taken from the
    table for this part number, not from a family summary.

    What the Numbers Mean

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    30 A through a 3.2 V drop is 96 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 1.6 °C/W the same 96 W lifts the junction by about 154 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 5 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    Forward voltage and recovery time trade against each other in the design of the die. The family is offered in two recovery classes for that reason: the softer, faster part costs a little forward drop, and the lower drop part gives some of the speed back.

    Where It Goes on the Board

    On a bridge or a PFC stage, keep the return path of each diode pair on the same layer. The recovery currents of the two halves then share a path instead of crossing the board through vias.

    • Recovery time is quoted at a specific dI/dt and forward current. Change the commutation rate and the number moves; a part measured at 100 A/us can behave differently at 500 A/us.
    • The plastic package is UL 94V-0 rated and the terminals are tin plated. Wave or reflow soldering limits are in the data sheet; the peak body temperature is the constraint, not the dwell time at a lower temperature.

    Frequently Asked Questions

    How much voltage margin should the diode have?
    The repetitive peak reverse voltage should clear the worst-case peak on the line with margin for regulation and surge. On a 230 V mains input that means 600 V is the practical choice rather than 400 V, because the peak already sits at 325 V before any transient.

    How is the heatsink sized?
    Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.

    What package should a 600 V, 10 A design use?
    The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message