Eaton EREC7506TL Hyperfast Recovery Rectifier 50 ns
Eaton EREC7506TL Hyperfast Recovery Rectifier 50 ns

Eaton EREC7506TL Hyperfast Recovery Rectifier 50 ns

Share
EREC7506TL: 600 V, 75 A hyperfast recovery rectifier, 2.75 V forward drop, 50 ns trr, TO-247J-2L.
    • Product Details
    • Download

    Eaton EREC7506TL Hyperfast Recovery Rectifier 50 ns

    EREC7506TL at a glance: hyperfast recovery rectifier, 600 V, 75 A, 2.75 V forward drop, 50 ns recovery, TO-247J-2L.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEREC7506TL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))75 A at Tmb ≤ 110 °C
    Peak forward surge current (IFSM)700 A, 8.3 ms half sine
    Forward voltage (VF)2.75 V max (typ 2 V), IF=75 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)50 ns max
    Reverse recovery charge (Qrr)85 nC typ
    Peak reverse recovery current (IRM)4.1 A typ
    Thermal resistance, junction to ambient45 °C/W
    Thermal resistance, junction to case0.44 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-247J-2L
    MountingThrough-hole
    Weight5.75 g typical
    PolarityCathode marked on the tab
    Recovery classHyperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1412

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1412; the values above are taken from the
    table for this part number, not from a family summary.

    Reading the Data Sheet

    The recovery waveform matters as much as its duration. Soft recovery means the current falls back to zero without a sharp snap, which keeps the voltage spike across the parasitic inductance of the loop low. A hard recovery of the same trr can ring harder.

    75 A through a 2.75 V drop is 206.25 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 45 °C/W the same 206.25 W lifts the junction by about 9281 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 9 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.

    Layout and Placement

    On a bridge or a PFC stage, keep the return path of each diode pair on the same layer. The recovery currents of the two halves then share a path instead of crossing the board through vias.

    • Recovery time is quoted at a specific dI/dt and forward current. Change the commutation rate and the number moves; a part measured at 100 A/us can behave differently at 500 A/us.
    • Thermal resistance from junction to ambient includes the copper area named in the note under the table. Junction to case, where it is given, is the number to use with a heatsink calculation.

    Frequently Asked Questions

    What does soft recovery actually mean?
    The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.

    How is the heatsink sized?
    Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message