Eaton EREE0106SA 600 V 1 A Superfast Rectifier
Eaton EREE0106SA 600 V 1 A Superfast Rectifier

Eaton EREE0106SA 600 V 1 A Superfast Rectifier

Share
EREE0106SA: 600 V, 1 A superfast recovery rectifier, 1.5 V forward drop, 35 ns trr, DO-214AC.
    • Product Details
    • Download

    Eaton EREE0106SA 600 V 1 A Superfast Rectifier

    EREE0106SA at a glance: superfast recovery rectifier, 600 V, 1 A, 1.5 V forward drop, 35 ns recovery, DO-214AC.

    Electrical Specifications

    ParameterValue
    Orderable part numberEREE0106SA
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))1 A at TA = 100 °C
    Peak forward surge current (IFSM)30 A, 8.3 ms half sine
    Forward voltage (VF)1.5 V max, IF=1 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Thermal resistance, junction to ambient125 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageDO-214AC (SMA)
    MountingSurface mount
    Weight0.0673 g typical
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1413

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1413; the values above are taken from the
    table for this part number, not from a family summary.

    The Figures Explained

    Hyperfast and superfast are relative terms. The die is a P-I-N structure with a thin drift region and lifetime control, so the stored charge that has to be swept out at turn-off is small. That is what makes the recovery time a few tens of nanoseconds instead of a few microseconds.

    1 A through a 1.5 V drop is 1.5 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 125 °C/W the same 1.5 W lifts the junction by about 188 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 30 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.

    Placement in the Circuit

    On a bridge or a PFC stage, keep the return path of each diode pair on the same layer. The recovery currents of the two halves then share a path instead of crossing the board through vias.

    • The surge current rating is a single half sinewave. Repetitive inrush, such as a capacitive load charging every time the supply is switched on, heats the die far more than one cold start.
    • The plastic package is UL 94V-0 rated and the terminals are tin plated. Wave or reflow soldering limits are in the data sheet; the peak body temperature is the constraint, not the dwell time at a lower temperature.

    Frequently Asked Questions

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.

    How much voltage margin should the diode have?
    The repetitive peak reverse voltage should clear the worst-case peak on the line with margin for regulation and surge. On a 230 V mains input that means 600 V is the practical choice rather than 400 V, because the peak already sits at 325 V before any transient.

    What package should a 600 V, 10 A design use?
    The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message