EREE0502K: 200 V, 5 A superfast recovery rectifier, 0.95 V forward drop, 35 ns trr, TO-252-3L.
    • Product Details
    • Download

    Eaton EREE0502K 200 V 5 A Fast Recovery Diode

    EREE0502K at a glance: superfast recovery rectifier, 200 V, 5 A, 0.95 V forward drop, 35 ns recovery, TO-252-3L.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEREE0502K
    Repetitive peak reverse voltage (VRRM)200 V
    Maximum RMS voltage (VRMS)140 V
    Maximum DC blocking voltage (VDC)200 V
    Average forward current (IF(AV))5 A at Tc = 100 °C
    Peak forward surge current (IFSM)75 A, 8.3 ms half sine
    Forward voltage (VF)0.95 V max, IF=5 A Tj=25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Thermal resistance, junction to case14 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-252-3L
    MountingSurface mount
    Weight0.329 g typical
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1414

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1414; the values above are taken from the
    table for this part number, not from a family summary.

    Reading the Data Sheet

    The recovery waveform matters as much as its duration. Soft recovery means the current falls back to zero without a sharp snap, which keeps the voltage spike across the parasitic inductance of the loop low. A hard recovery of the same trr can ring harder.

    5 A through a 0.95 V drop is 4.75 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 14 °C/W the same 4.75 W lifts the junction by about 66 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 200 V repetitive rating comes with a 140 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 15 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.

    Layout and Placement

    Keep the commutating loop small. The reverse recovery current falls out of the diode into the switch that turned it off, and that current times the loop inductance is the voltage overshoot the switch has to survive. A few centimetres of loop is enough to double the spike.

    • Recovery time is quoted at a specific dI/dt and forward current. Change the commutation rate and the number moves; a part measured at 100 A/us can behave differently at 500 A/us.
    • Reverse recovery charge is the integral of the recovery current. It is the figure that turns into switching loss in the counterpart switch, and it scales with forward current, not with voltage.

    Frequently Asked Questions

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.

    How is the heatsink sized?
    Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.