Eaton EREE0804FPL Superfast Recovery Rectifier 35 ns
Eaton EREE0804FPL Superfast Recovery Rectifier 35 ns

Eaton EREE0804FPL Superfast Recovery Rectifier 35 ns

Share
EREE0804FPL: 400 V, 8 A superfast recovery rectifier, 1.3 V forward drop, 35 ns trr, TO-220FP-2L.
    • Product Details
    • Download

    Eaton EREE0804FPL Superfast Recovery Rectifier 35 ns

    EREE0804FPL at a glance: superfast recovery rectifier, 400 V, 8 A, 1.3 V forward drop, 35 ns recovery, TO-220FP-2L.

    Key Specifications

    ParameterValue
    Orderable part numberEREE0804FPL
    Repetitive peak reverse voltage (VRRM)400 V
    Maximum RMS voltage (VRMS)280 V
    Maximum DC blocking voltage (VDC)400 V
    Average forward current (IF(AV))8 A at TC = 100 °C
    Peak forward surge current (IFSM)125 A, 8.3 ms half sine
    Forward voltage (VF)1.3 V max, IF = 8 A Tj = 25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Thermal resistance, junction to case4 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220FP-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1427

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1427; the values above are taken from the
    table for this part number, not from a family summary.

    What the Numbers Mean

    These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.

    8 A through a 1.3 V drop is 10.4 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 4 °C/W the same 10.4 W lifts the junction by about 42 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 400 V repetitive rating comes with a 280 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 16 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.

    Where It Goes on the Board

    Bolt or solder the tab to copper that spreads heat, not just to the pad the footprint asks for. The junction-to-ambient figure assumes a specific copper area, and a smaller island quietly derates the part.

    • The reverse voltage rating is a peak repetitive figure at the specified temperature. A mains-fed bridge on 230 V RMS sees 325 V peaks plus the surge margin, so a 400 V part is the minimum and 600 V is the usual choice.
    • The plastic package is UL 94V-0 rated and the terminals are tin plated. Wave or reflow soldering limits are in the data sheet; the peak body temperature is the constraint, not the dwell time at a lower temperature.

    Frequently Asked Questions

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.

    What does soft recovery actually mean?
    The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.