| Parameter | Value |
|---|---|
| Orderable part number | EREE0806CL |
| Repetitive peak reverse voltage (VRRM) | 600 V |
| Maximum RMS voltage (VRMS) | 420 V |
| Maximum DC blocking voltage (VDC) | 600 V |
| Average forward current (IF(AV)) | 8 A at Tc = 100 °C |
| Peak forward surge current (IFSM) | 125 A, 8.3 ms half sine |
| Forward voltage (VF) | 1.7 V max, IF = 8 A Tj = 25 °C |
| Reverse current at VRRM, 25 °C | 5 uA max |
| Reverse recovery time (trr) | 35 ns max |
| Thermal resistance, junction to case | 2 °C/W |
| Operating junction and storage temperature | -55 °C to +150 °C |
| Package | TO-220C-2L |
| Mounting | Through-hole |
| Weight | 2.0 g typical |
| Polarity | Cathode marked on the tab |
| Recovery class | Superfast |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1428 |
Rating conditions (ambient or case temperature, test current, dI/dt) are
as printed in Eaton Technical Data ELX1428; the values above are taken from the
table for this part number, not from a family summary.
Hyperfast and superfast are relative terms. The die is a P-I-N structure with a thin drift region and lifetime control, so the stored charge that has to be swept out at turn-off is small. That is what makes the recovery time a few tens of nanoseconds instead of a few microseconds.
8 A through a 1.7 V drop is 13.6 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.
Against 2 °C/W the same 13.6 W lifts the junction by about 27 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.
The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.
The surge rating is 16 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.
A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.
Keep the commutating loop small. The reverse recovery current falls out of the diode into the switch that turned it off, and that current times the loop inductance is the voltage overshoot the switch has to survive. A few centimetres of loop is enough to double the spike.
How is the heatsink sized?
Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.
How much voltage margin should the diode have?
The repetitive peak reverse voltage should clear the worst-case peak on the line with margin for regulation and surge. On a 230 V mains input that means 600 V is the practical choice rather than 400 V, because the peak already sits at 325 V before any transient.
Is the surge rating a repetitive rating?
It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.