Eaton EREE0806FPL Superfast Recovery Rectifier 35 ns
Eaton EREE0806FPL Superfast Recovery Rectifier 35 ns

Eaton EREE0806FPL Superfast Recovery Rectifier 35 ns

Share
EREE0806FPL: 600 V, 8 A superfast recovery rectifier, 1.7 V forward drop, 35 ns trr, TO-220FP-2L.
    • Product Details
    • Download

    Eaton EREE0806FPL Superfast Recovery Rectifier 35 ns

    EREE0806FPL at a glance: superfast recovery rectifier, 600 V, 8 A, 1.7 V forward drop, 35 ns recovery, TO-220FP-2L.

    Key Specifications

    ParameterValue
    Orderable part numberEREE0806FPL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))8 A at Tc = 100 °C
    Peak forward surge current (IFSM)125 A, 8.3 ms half sine
    Forward voltage (VF)1.7 V max, IF = 8 A Tj = 25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Thermal resistance, junction to case4 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220FP-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1430

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1430; the values above are taken from the
    table for this part number, not from a family summary.

    What the Numbers Mean

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    8 A through a 1.7 V drop is 13.6 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 4 °C/W the same 13.6 W lifts the junction by about 54 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 16 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    Where It Goes on the Board

    Keep the commutating loop small. The reverse recovery current falls out of the diode into the switch that turned it off, and that current times the loop inductance is the voltage overshoot the switch has to survive. A few centimetres of loop is enough to double the spike.

    • The surge current rating is a single half sinewave. Repetitive inrush, such as a capacitive load charging every time the supply is switched on, heats the die far more than one cold start.
    • The forward voltage is specified at a pulse or a defined junction temperature. It has a negative temperature coefficient at low current and a positive one at high current, which is why paralleling needs care.

    Frequently Asked Questions

    How much voltage margin should the diode have?
    The repetitive peak reverse voltage should clear the worst-case peak on the line with margin for regulation and surge. On a 230 V mains input that means 600 V is the practical choice rather than 400 V, because the peak already sits at 325 V before any transient.

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.

    How is the heatsink sized?
    Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.

    Shenzhen Gaorunxin Technology Co., Ltd