| Parameter | Value |
|---|---|
| Orderable part number | EREE1002FPL |
| Repetitive peak reverse voltage (VRRM) | 200 V |
| Maximum RMS voltage (VRMS) | 140 V |
| Maximum DC blocking voltage (VDC) | 200 V |
| Average forward current (IF(AV)) | 10 A at TC = 100 °C |
| Peak forward surge current (IFSM) | 150 A, 8.3 ms half sine |
| Forward voltage (VF) | 1.1 V max, IF = 10 A Tj = 25 °C |
| Reverse current at VRRM, 25 °C | 5 uA max |
| Reverse recovery time (trr) | 35 ns max |
| Thermal resistance, junction to case | 4 °C/W |
| Operating junction and storage temperature | -55 °C to +150 °C |
| Package | TO-220FP-2L |
| Mounting | Through-hole |
| Weight | 2.0 g typical |
| Polarity | Cathode marked on the tab |
| Recovery class | Superfast |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1431 |
Rating conditions (ambient or case temperature, test current, dI/dt) are
as printed in Eaton Technical Data ELX1431; the values above are taken from the
table for this part number, not from a family summary.
These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.
10 A through a 1.1 V drop is 11 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.
Against 4 °C/W the same 11 W lifts the junction by about 44 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.
The 200 V repetitive rating comes with a 140 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.
The surge rating is 15 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.
The recovery waveform matters as much as its duration. Soft recovery means the current falls back to zero without a sharp snap, which keeps the voltage spike across the parasitic inductance of the loop low. A hard recovery of the same trr can ring harder.
Keep the commutating loop small. The reverse recovery current falls out of the diode into the switch that turned it off, and that current times the loop inductance is the voltage overshoot the switch has to survive. A few centimetres of loop is enough to double the spike.
Why is the leakage specified twice?
Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.
Does a faster recovery always mean less loss?
No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.
How much voltage margin should the diode have?
The repetitive peak reverse voltage should clear the worst-case peak on the line with margin for regulation and surge. On a 230 V mains input that means 600 V is the practical choice rather than 400 V, because the peak already sits at 325 V before any transient.