| Parameter | Value |
|---|---|
| Orderable part number | EREE1004FPL |
| Repetitive peak reverse voltage (VRRM) | 400 V |
| Maximum RMS voltage (VRMS) | 280 V |
| Maximum DC blocking voltage (VDC) | 400 V |
| Average forward current (IF(AV)) | 10 A at TC = 100 °C |
| Peak forward surge current (IFSM) | 150 A, 8.3 ms half sine |
| Forward voltage (VF) | 1.3 V max, IF = 10 A Tj = 25 °C |
| Reverse current at VRRM, 25 °C | 5 uA max |
| Reverse recovery time (trr) | 35 ns max |
| Thermal resistance, junction to case | 4 °C/W |
| Operating junction and storage temperature | -55 °C to +150 °C |
| Package | TO-220FP-2L |
| Mounting | Through-hole |
| Weight | 2.0 g typical |
| Polarity | Cathode marked on the tab |
| Recovery class | Superfast |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1432 |
Rating conditions (ambient or case temperature, test current, dI/dt) are
as printed in Eaton Technical Data ELX1432; the values above are taken from the
table for this part number, not from a family summary.
Forward voltage and recovery time trade against each other in the design of the die. The family is offered in two recovery classes for that reason: the softer, faster part costs a little forward drop, and the lower drop part gives some of the speed back.
10 A through a 1.3 V drop is 13 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.
Against 4 °C/W the same 13 W lifts the junction by about 52 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.
The 400 V repetitive rating comes with a 280 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.
The surge rating is 15 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.
Forward voltage and recovery time trade against each other in the design of the die. The family is offered in two recovery classes for that reason: the softer, faster part costs a little forward drop, and the lower drop part gives some of the speed back.
On a bridge or a PFC stage, keep the return path of each diode pair on the same layer. The recovery currents of the two halves then share a path instead of crossing the board through vias.
Is the surge rating a repetitive rating?
It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.
Can these be paralleled?
Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.
What does soft recovery actually mean?
The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.