EREE1004K: 400 V, 10 A superfast recovery rectifier, 1.3 V forward drop, 35 ns trr, TO-252.
    • Product Details
    • Download

    Eaton EREE1004K Superfast Recovery Rectifier 35 ns

    EREE1004K at a glance: superfast recovery rectifier, 400 V, 10 A, 1.3 V forward drop, 35 ns recovery, TO-252.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEREE1004K
    Repetitive peak reverse voltage (VRRM)400 V
    Maximum RMS voltage (VRMS)280 V
    Maximum DC blocking voltage (VDC)400 V
    Average forward current (IF(AV))10 A at TC = 100 °C
    Peak forward surge current (IFSM)150 A, 8.3 ms half sine
    Forward voltage (VF)1.3 V max, IF = 10 A Tj = 25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Thermal resistance, junction to case14 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-252
    MountingSurface mount
    Weight0.329 g typical
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1433

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1433; the values above are taken from the
    table for this part number, not from a family summary.

    Reading the Data Sheet

    These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.

    10 A through a 1.3 V drop is 13 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 14 °C/W the same 13 W lifts the junction by about 182 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 400 V repetitive rating comes with a 280 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 15 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.

    Layout and Placement

    Bolt or solder the tab to copper that spreads heat, not just to the pad the footprint asks for. The junction-to-ambient figure assumes a specific copper area, and a smaller island quietly derates the part.

    • Recovery time is quoted at a specific dI/dt and forward current. Change the commutation rate and the number moves; a part measured at 100 A/us can behave differently at 500 A/us.
    • Thermal resistance from junction to ambient includes the copper area named in the note under the table. Junction to case, where it is given, is the number to use with a heatsink calculation.

    Frequently Asked Questions

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.

    What does soft recovery actually mean?
    The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.

    Is the surge rating a repetitive rating?
    It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.