Eaton EREE1006CLS 600 V 10 A Superfast Rectifier
Eaton EREE1006CLS 600 V 10 A Superfast Rectifier

Eaton EREE1006CLS 600 V 10 A Superfast Rectifier

Share
EREE1006CLS: 600 V, 10 A superfast recovery rectifier, 1.7 V forward drop, 50 ns trr, TO-220C-2L.
    • Product Details
    • Download

    Eaton EREE1006CLS 600 V 10 A Superfast Rectifier

    EREE1006CLS at a glance: superfast recovery rectifier, 600 V, 10 A, 1.7 V forward drop, 50 ns recovery, TO-220C-2L.

    Specification Table

    ParameterValue
    Orderable part numberEREE1006CLS
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))10 A at TC = 109 °C
    Peak forward surge current (IFSM)80 A, 8.3 ms half sine
    Forward voltage (VF)1.7 V max (typ 1.5 V), IF = 10 A Tj = 25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)40 ns typ / 50 ns max
    Reverse recovery charge (Qrr)200 nC typ
    Peak reverse recovery current (IRM)6 A typ
    Thermal resistance, junction to ambient60 °C/W
    Thermal resistance, junction to case3.5 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220C-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1435

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1435; the values above are taken from the
    table for this part number, not from a family summary.

    How to Read These Ratings

    Hyperfast and superfast are relative terms. The die is a P-I-N structure with a thin drift region and lifetime control, so the stored charge that has to be swept out at turn-off is small. That is what makes the recovery time a few tens of nanoseconds instead of a few microseconds.

    10 A through a 1.7 V drop is 17 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 60 °C/W the same 17 W lifts the junction by about 1020 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 8 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    The recovery waveform matters as much as its duration. Soft recovery means the current falls back to zero without a sharp snap, which keeps the voltage spike across the parasitic inductance of the loop low. A hard recovery of the same trr can ring harder.

    Board Layout

    Bolt or solder the tab to copper that spreads heat, not just to the pad the footprint asks for. The junction-to-ambient figure assumes a specific copper area, and a smaller island quietly derates the part.

    • Average forward current is quoted at a case or ambient temperature. Run the part hotter and the allowable current falls faster than the linear derating curve suggests, because the forward drop rises with temperature as well.
    • Thermal resistance from junction to ambient includes the copper area named in the note under the table. Junction to case, where it is given, is the number to use with a heatsink calculation.

    Frequently Asked Questions

    Is the surge rating a repetitive rating?
    It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.