Eaton EREE1006FPLS Superfast Recovery Rectifier 50 ns
Eaton EREE1006FPLS Superfast Recovery Rectifier 50 ns

Eaton EREE1006FPLS Superfast Recovery Rectifier 50 ns

Share
EREE1006FPLS: 600 V, 10 A superfast recovery rectifier, 1.7 V forward drop, 50 ns trr, TO-220FP-2L.
    • Product Details
    • Download

    Eaton EREE1006FPLS Superfast Recovery Rectifier 50 ns

    EREE1006FPLS at a glance: superfast recovery rectifier, 600 V, 10 A, 1.7 V forward drop, 50 ns recovery, TO-220FP-2L.

    Electrical Specifications

    ParameterValue
    Orderable part numberEREE1006FPLS
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))10 A at TC = 71 °C
    Peak forward surge current (IFSM)80 A, 8.3 ms half sine
    Forward voltage (VF)1.7 V max (typ 1.5 V), IF = 10 A Tj = 25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)40 ns typ / 50 ns max
    Reverse recovery charge (Qrr)200 nC typ
    Peak reverse recovery current (IRM)6 A typ
    Thermal resistance, junction to ambient55 °C/W
    Thermal resistance, junction to case7.2 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220FP-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1448

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1448; the values above are taken from the
    table for this part number, not from a family summary.

    The Figures Explained

    Hyperfast and superfast are relative terms. The die is a P-I-N structure with a thin drift region and lifetime control, so the stored charge that has to be swept out at turn-off is small. That is what makes the recovery time a few tens of nanoseconds instead of a few microseconds.

    10 A through a 1.7 V drop is 17 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 55 °C/W the same 17 W lifts the junction by about 935 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 8 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    Placement in the Circuit

    Place the snubber or the clamp across the diode only after the loop has been made as short as it can be. A snubber that compensates for a bad layout burns power every cycle to fix what copper would have fixed for free.

    • The reverse voltage rating is a peak repetitive figure at the specified temperature. A mains-fed bridge on 230 V RMS sees 325 V peaks plus the surge margin, so a 400 V part is the minimum and 600 V is the usual choice.
    • Reverse recovery charge is the integral of the recovery current. It is the figure that turns into switching loss in the counterpart switch, and it scales with forward current, not with voltage.

    Frequently Asked Questions

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.

    Is the surge rating a repetitive rating?
    It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.

    How much voltage margin should the diode have?
    The repetitive peak reverse voltage should clear the worst-case peak on the line with margin for regulation and surge. On a 230 V mains input that means 600 V is the practical choice rather than 400 V, because the peak already sits at 325 V before any transient.