Eaton EREE1006K Superfast Recovery Rectifier 35 ns
Eaton EREE1006K Superfast Recovery Rectifier 35 ns

Eaton EREE1006K Superfast Recovery Rectifier 35 ns

Share
EREE1006K: 600 V, 10 A superfast recovery rectifier, 1.7 V forward drop, 35 ns trr, TO-252.
    • Product Details
    • Download

    Eaton EREE1006K Superfast Recovery Rectifier 35 ns

    EREE1006K at a glance: superfast recovery rectifier, 600 V, 10 A, 1.7 V forward drop, 35 ns recovery, TO-252.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEREE1006K
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))10 A at Tc = 100 °C
    Peak forward surge current (IFSM)150 A, 8.3 ms half sine
    Forward voltage (VF)1.7 V max, IF = 10 A Tj = 25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Thermal resistance, junction to case14 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-252
    MountingSurface mount
    Weight0.33 g typical
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1449

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1449; the values above are taken from the
    table for this part number, not from a family summary.

    Reading the Data Sheet

    The recovery waveform matters as much as its duration. Soft recovery means the current falls back to zero without a sharp snap, which keeps the voltage spike across the parasitic inductance of the loop low. A hard recovery of the same trr can ring harder.

    10 A through a 1.7 V drop is 17 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 14 °C/W the same 17 W lifts the junction by about 238 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 15 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    Forward voltage and recovery time trade against each other in the design of the die. The family is offered in two recovery classes for that reason: the softer, faster part costs a little forward drop, and the lower drop part gives some of the speed back.

    Layout and Placement

    Bolt or solder the tab to copper that spreads heat, not just to the pad the footprint asks for. The junction-to-ambient figure assumes a specific copper area, and a smaller island quietly derates the part.

    • The reverse voltage rating is a peak repetitive figure at the specified temperature. A mains-fed bridge on 230 V RMS sees 325 V peaks plus the surge margin, so a 400 V part is the minimum and 600 V is the usual choice.
    • Thermal resistance from junction to ambient includes the copper area named in the note under the table. Junction to case, where it is given, is the number to use with a heatsink calculation.

    Frequently Asked Questions

    What does soft recovery actually mean?
    The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.

    What package should a 600 V, 10 A design use?
    The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.