Eaton EREE1006KS 600 V 10 A Fast Recovery Diode
Eaton EREE1006KS 600 V 10 A Fast Recovery Diode

Eaton EREE1006KS 600 V 10 A Fast Recovery Diode

Share
EREE1006KS: 600 V, 10 A superfast recovery rectifier, 1.7 V forward drop, 50 ns trr, TO-252.
    • Product Details
    • Download

    Eaton EREE1006KS 600 V 10 A Fast Recovery Diode

    EREE1006KS at a glance: superfast recovery rectifier, 600 V, 10 A, 1.7 V forward drop, 50 ns recovery, TO-252.

    Electrical Specifications

    ParameterValue
    Orderable part numberEREE1006KS
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))10 A at Tmb ≤ 118 °C
    Peak forward surge current (IFSM)80 A, 8.3 ms half sine
    Forward voltage (VF)1.7 V max (typ 1.5 V), IF = 10 A Tj = 25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)40 ns typ / 50 ns max
    Reverse recovery charge (Qrr)200 nC typ
    Peak reverse recovery current (IRM)6 A typ
    Thermal resistance, junction to ambient50 °C/W
    Thermal resistance, junction to case3 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-252
    MountingSurface mount
    Weight0.33 g typical
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1450

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1450; the values above are taken from the
    table for this part number, not from a family summary.

    The Figures Explained

    The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.

    10 A through a 1.7 V drop is 17 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 50 °C/W the same 17 W lifts the junction by about 850 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 8 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    Forward voltage and recovery time trade against each other in the design of the die. The family is offered in two recovery classes for that reason: the softer, faster part costs a little forward drop, and the lower drop part gives some of the speed back.

    Placement in the Circuit

    Keep the commutating loop small. The reverse recovery current falls out of the diode into the switch that turned it off, and that current times the loop inductance is the voltage overshoot the switch has to survive. A few centimetres of loop is enough to double the spike.

    • Average forward current is quoted at a case or ambient temperature. Run the part hotter and the allowable current falls faster than the linear derating curve suggests, because the forward drop rises with temperature as well.
    • The forward voltage is specified at a pulse or a defined junction temperature. It has a negative temperature coefficient at low current and a positive one at high current, which is why paralleling needs care.

    Frequently Asked Questions

    Can these be paralleled?
    Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.

    How much voltage margin should the diode have?
    The repetitive peak reverse voltage should clear the worst-case peak on the line with margin for regulation and surge. On a 230 V mains input that means 600 V is the practical choice rather than 400 V, because the peak already sits at 325 V before any transient.

    What package should a 600 V, 10 A design use?
    The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.