
| Parameter | Value |
|---|---|
| Orderable part number | EREE1006KS |
| Repetitive peak reverse voltage (VRRM) | 600 V |
| Maximum RMS voltage (VRMS) | 420 V |
| Maximum DC blocking voltage (VDC) | 600 V |
| Average forward current (IF(AV)) | 10 A at Tmb ≤ 118 °C |
| Peak forward surge current (IFSM) | 80 A, 8.3 ms half sine |
| Forward voltage (VF) | 1.7 V max (typ 1.5 V), IF = 10 A Tj = 25 °C |
| Reverse current at VRRM, 25 °C | 5 uA max |
| Reverse recovery time (trr) | 40 ns typ / 50 ns max |
| Reverse recovery charge (Qrr) | 200 nC typ |
| Peak reverse recovery current (IRM) | 6 A typ |
| Thermal resistance, junction to ambient | 50 °C/W |
| Thermal resistance, junction to case | 3 °C/W |
| Operating junction and storage temperature | -55 °C to +150 °C |
| Package | TO-252 |
| Mounting | Surface mount |
| Weight | 0.33 g typical |
| Recovery class | Superfast |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1450 |
Rating conditions (ambient or case temperature, test current, dI/dt) are
as printed in Eaton Technical Data ELX1450; the values above are taken from the
table for this part number, not from a family summary.
The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.
10 A through a 1.7 V drop is 17 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.
Against 50 °C/W the same 17 W lifts the junction by about 850 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.
The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.
The surge rating is 8 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.
Forward voltage and recovery time trade against each other in the design of the die. The family is offered in two recovery classes for that reason: the softer, faster part costs a little forward drop, and the lower drop part gives some of the speed back.
Keep the commutating loop small. The reverse recovery current falls out of the diode into the switch that turned it off, and that current times the loop inductance is the voltage overshoot the switch has to survive. A few centimetres of loop is enough to double the spike.
Can these be paralleled?
Only with care. Forward voltage has a positive temperature coefficient at rated current, which helps sharing, but the recovery characteristics of two dice are never identical. Use a single larger part where the current allows it.
How much voltage margin should the diode have?
The repetitive peak reverse voltage should clear the worst-case peak on the line with margin for regulation and surge. On a 230 V mains input that means 600 V is the practical choice rather than 400 V, because the peak already sits at 325 V before any transient.
What package should a 600 V, 10 A design use?
The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd