Eaton EREE1506CL 600 V 15 A Superfast Rectifier
Eaton EREE1506CL 600 V 15 A Superfast Rectifier

Eaton EREE1506CL 600 V 15 A Superfast Rectifier

Share
EREE1506CL: 600 V, 15 A superfast recovery rectifier, 1.7 V forward drop, 35 ns trr, TO-220C-2L.
    • Product Details
    • Download

    Eaton EREE1506CL 600 V 15 A Superfast Rectifier

    EREE1506CL at a glance: superfast recovery rectifier, 600 V, 15 A, 1.7 V forward drop, 35 ns recovery, TO-220C-2L.

    Specification Table

    ParameterValue
    Orderable part numberEREE1506CL
    Repetitive peak reverse voltage (VRRM)600 V
    Maximum RMS voltage (VRMS)420 V
    Maximum DC blocking voltage (VDC)600 V
    Average forward current (IF(AV))15 A at TC = 100 °C
    Peak forward surge current (IFSM)200 A, 8.3 ms half sine
    Forward voltage (VF)1.7 V max, IF = 15 A Tj = 25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Thermal resistance, junction to case1.3 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220C-2L
    MountingThrough-hole
    Weight2.0 g typical
    PolarityCathode marked on the tab
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1452

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1452; the values above are taken from the
    table for this part number, not from a family summary.

    How to Read These Ratings

    Hyperfast and superfast are relative terms. The die is a P-I-N structure with a thin drift region and lifetime control, so the stored charge that has to be swept out at turn-off is small. That is what makes the recovery time a few tens of nanoseconds instead of a few microseconds.

    15 A through a 1.7 V drop is 25.5 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 1.3 °C/W the same 25.5 W lifts the junction by about 33 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 600 V repetitive rating comes with a 420 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 13 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.

    Board Layout

    Bolt or solder the tab to copper that spreads heat, not just to the pad the footprint asks for. The junction-to-ambient figure assumes a specific copper area, and a smaller island quietly derates the part.

    • The reverse voltage rating is a peak repetitive figure at the specified temperature. A mains-fed bridge on 230 V RMS sees 325 V peaks plus the surge margin, so a 400 V part is the minimum and 600 V is the usual choice.
    • Thermal resistance from junction to ambient includes the copper area named in the note under the table. Junction to case, where it is given, is the number to use with a heatsink calculation.

    Frequently Asked Questions

    Is the surge rating a repetitive rating?
    It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.

    What does soft recovery actually mean?
    The reverse current decays without an abrupt snap. That reduces the ringing between the diode capacitance and the loop inductance, which is what produces the voltage spike across the switch. Two parts with the same trr can behave very differently here.

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.

    Shenzhen Gaorunxin Technology Co., Ltd