EREE1604BC: 400 V, 16 A superfast recovery rectifier, 1.3 V forward drop, 35 ns trr, TO-220B-3L.
    • Product Details
    • Download

    Eaton EREE1604BC Superfast Recovery Rectifier 35 ns

    EREE1604BC at a glance: superfast recovery rectifier, 400 V, 16 A, 1.3 V forward drop, 35 ns recovery, TO-220B-3L.

    Key Specifications

    ParameterValue
    Orderable part numberEREE1604BC
    Repetitive peak reverse voltage (VRRM)400 V
    Maximum RMS voltage (VRMS)280 V
    Maximum DC blocking voltage (VDC)400 V
    Average forward current (IF(AV))16 A at TC = 105 °C
    Peak forward surge current (IFSM)125 A, 8.3 ms half sine
    Forward voltage (VF)1.3 V max, IF = 8 A Tj = 25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Thermal resistance, junction to case1.5 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220B-3L
    MountingThrough-hole
    Weight1.94 g typical
    PolarityCathode marked on the tab
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1454

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1454; the values above are taken from the
    table for this part number, not from a family summary.

    What the Numbers Mean

    The recovery waveform matters as much as its duration. Soft recovery means the current falls back to zero without a sharp snap, which keeps the voltage spike across the parasitic inductance of the loop low. A hard recovery of the same trr can ring harder.

    16 A through a 1.3 V drop is 20.8 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 1.5 °C/W the same 20.8 W lifts the junction by about 31 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 400 V repetitive rating comes with a 280 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 8 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    These are plastic packaged discrete diodes, from SOD-123FL up to TO-247. The package sets the thermal path, and the thermal path sets how much of the rated current can actually be drawn before the junction runs out of margin.

    Where It Goes on the Board

    On a bridge or a PFC stage, keep the return path of each diode pair on the same layer. The recovery currents of the two halves then share a path instead of crossing the board through vias.

    • The surge current rating is a single half sinewave. Repetitive inrush, such as a capacitive load charging every time the supply is switched on, heats the die far more than one cold start.
    • Thermal resistance from junction to ambient includes the copper area named in the note under the table. Junction to case, where it is given, is the number to use with a heatsink calculation.

    Frequently Asked Questions

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.

    How is the heatsink sized?
    Multiply the conduction loss by the junction-to-case thermal resistance to get the rise to the case, then add the case-to-heatsink and heatsink-to-ambient rises. The junction-to-ambient figure in the table already includes a defined copper area and is only valid for that layout.

    Why is the leakage specified twice?
    Once at 25 °C and once at the high junction temperature, because the reverse current roughly doubles every 10 °C. At 150 °C the leakage can be two orders of magnitude above the room temperature figure, and that is the value that loads the circuit in a hot enclosure.