Eaton EREE1604FPC 400 V 16 A Superfast Rectifier
Eaton EREE1604FPC 400 V 16 A Superfast Rectifier

Eaton EREE1604FPC 400 V 16 A Superfast Rectifier

Share
EREE1604FPC: 400 V, 16 A superfast recovery rectifier, 1.3 V forward drop, 35 ns trr, TO-220FP-3L.
    • Product Details
    • Download

    Eaton EREE1604FPC 400 V 16 A Superfast Rectifier

    EREE1604FPC at a glance: superfast recovery rectifier, 400 V, 16 A, 1.3 V forward drop, 35 ns recovery, TO-220FP-3L.

    Key Specifications

    ParameterValue
    Orderable part numberEREE1604FPC
    Repetitive peak reverse voltage (VRRM)400 V
    Maximum RMS voltage (VRMS)280 V
    Maximum DC blocking voltage (VDC)400 V
    Average forward current (IF(AV))16 A at TC = 105 °C
    Peak forward surge current (IFSM)125 A, 8.3 ms half sine
    Forward voltage (VF)1.3 V max, IF = 8 A Tj = 25 °C
    Reverse current at VRRM, 25 °C5 uA max
    Reverse recovery time (trr)35 ns max
    Thermal resistance, junction to case3.6 °C/W
    Operating junction and storage temperature-55 °C to +150 °C
    PackageTO-220FP-3L
    MountingThrough-hole
    Weight2.07 g typical
    PolarityCathode marked on the tab
    Recovery classSuperfast
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1455

    Rating conditions (ambient or case temperature, test current, dI/dt) are
    as printed in Eaton Technical Data ELX1455; the values above are taken from the
    table for this part number, not from a family summary.

    What the Numbers Mean

    A rectifier is chosen on three numbers: the reverse voltage it must hold off, the average current it must carry, and the forward drop at that current. Everything else on the data sheet describes how the part behaves while it is switching, which is where the recovery charge turns into heat.

    16 A through a 1.3 V drop is 20.8 W of conduction loss, and that is the figure the thermal path has to carry. The switch in the same loop dissipates on its own, so the diode is rarely the only heat source on the tab.

    Against 3.6 °C/W the same 20.8 W lifts the junction by about 75 °C above the reference point of that figure. With 150 °C allowed, that leaves the margin the ambient or the heatsink has to stay inside.

    The 400 V repetitive rating comes with a 280 V RMS figure, which is the 0.707 factor of the same sine. On a 230 V mains input the peak is already 325 V before any surge, so the margin here is what the transient clamp has to respect.

    The surge rating is 8 times the average current, but only for one 8.3 ms half sine. Inrush that repeats on every power-up accumulates heat and has to be checked against the transient thermal impedance curve instead.

    The reverse leakage is the price of the fast die. It is specified at 25 °C and again at the high temperature, and the second figure is often fifty to a hundred times the first. On a 150 °C design the hot value is the one that matters.

    Where It Goes on the Board

    Place the snubber or the clamp across the diode only after the loop has been made as short as it can be. A snubber that compensates for a bad layout burns power every cycle to fix what copper would have fixed for free.

    • The surge current rating is a single half sinewave. Repetitive inrush, such as a capacitive load charging every time the supply is switched on, heats the die far more than one cold start.
    • The plastic package is UL 94V-0 rated and the terminals are tin plated. Wave or reflow soldering limits are in the data sheet; the peak body temperature is the constraint, not the dwell time at a lower temperature.

    Frequently Asked Questions

    Does a faster recovery always mean less loss?
    No. The recovery loss falls, but the forward drop of a faster die is usually higher, and conduction loss scales with current while recovery loss scales with frequency. Below a few tens of kilohertz the forward drop dominates; above a hundred kilohertz the recovery charge does.

    Is the surge rating a repetitive rating?
    It is a single non-repetitive half sinewave at the stated duration. Repeated inrush, such as a capacitive load charging on every power-up, accumulates heat and has to be checked against the transient thermal impedance curve.

    What package should a 600 V, 10 A design use?
    The choice is thermal, not electrical. A TO-252 carries the current but needs the copper to do it; a TO-220 or TO-247 gives a metal tab and a real thermal path. The same die in the two packages has very different usable current.