Eaton EXL1V0603-R33-R 0.33 High-Current Molded Inductor, 20 A
Eaton EXL1V0603-R33-R 0.33 High-Current Molded Inductor, 20 A

Eaton EXL1V0603-R33-R 0.33 High-Current Molded Inductor, 20 A

Share
Eaton EXL1V0603-R33-R: High-Current Molded Power Inductor, 0.33 uH, 20 A, DCR 2.25 mOhm.
    • Product Details
    • Download

    Eaton EXL1V0603-R33-R 0.33 High-Current Molded Inductor, 20 A

    EXL1V0603-R33-R at a glance: high-current molded inductor, 0.33 uH, Irms 20/25 A (+20/+40 °C rise), Isat 28 A, DCR 2.25 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberEXL1V0603-R33-R
    OCL0.33 uH ±20%
    FLL minimum (at Isat)0.18 uH
    Irms typical, +20 °C rise20 A
    Irms typical, +40 °C rise25 A
    Isat (30% rolloff @ +25 °C)28 A
    DCR typical @ +25 °C2.25 mOhm
    DCR maximum @ +25 °C2.5 mOhm
    SRF typical78 MHz
    Rated operating voltage (across inductor)40 V typical
    Package7.4 x 7.1 mm footprint, 3.1 mm height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    Mechanical Dimensions & Pad Layout

    EXL1V0603-R33-R mechanical dimensions and pad layout

    Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.

    How to Read These Ratings

    A moulded power inductor built around an alloy powder core: the soft-saturation curve is the headline behaviour. Where ferrite falls off a cliff past Isat, the powder core drops gradually - the inductance degrades smoothly with current instead of collapsing, which is exactly what a multiphase VRM wants from its output inductors during a load transient.

    DCR 2.25 mOhm is the conduction loss: at rated current it dissipates 0.90 W, and that heat has to leave through the terminals and the board.

    Isat is defined as the peak current for approximately 30% rolloff at +25 °C. With an alloy powder core the rolloff is soft: past Isat the inductance keeps working, just lower - which is a design resource, not an excuse to run at the limit.

    The two Irms columns are the same winding at two allowed self-heating levels: +20 °C for boards with a tight thermal budget, +40 °C when the enclosure has airflow or headroom. Pick the column that matches the board, not the bigger number.

    Positioning in the Range

    EXL is the high-current moulded family for VRMs, multiphase regulators and point-of-load converters: soft-saturating alloy powder cores, low DCR, shielded, from a 4.6 mm footprint at 2.1 mm up to a 12.2 mm body at 10 mm.

    • Typical applications: VRM and multiphase regulators, point-of-load converters, desktop and server VRMs, base station equipment, laptop and graphics rails.
    • Irms assumes the datasheet pad and airflow; the 40 °C rise is a board-level outcome, not a property of the part alone.
    • Data sheet 11190; footprint 7.4 x 7.1 mm footprint, 3.1 mm height.

    Putting It to Work

    Frequently Asked Questions

    What is the rated operating voltage?
    The voltage the part was characterised at. It is a bias condition for the saturation measurement, not a voltage the inductor blocks.

    What is the difference between OCL and FLL?
    OCL is measured at zero bias; FLL is the inductance at Isat. Use FLL for ripple calculations at full load - that is what the converter actually sees.

    Why two Irms columns?
    The thermal rating is given for a +20 °C rise and a +40 °C rise. Use the 20 °C column when the board can only tolerate a small self-heating, the 40 °C column when the thermal budget has room.

    Design note: use FLL for ripple at load, the +20 °C Irms column for tight thermal budgets, and keep the transient peak inside the soft part of the saturation curve.

    Mechanical Dimensions

    eaton-exl1v0603-high-current-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.