
| Parameter | Value |
|---|---|
| Orderable part number | EXL1V0605-1R0-R |
| OCL | 1 uH ±20% |
| FLL minimum (at Isat) | 0.56 uH |
| Irms typical, +20 °C rise | 15 A |
| Irms typical, +40 °C rise | 20 A |
| Isat (30% rolloff @ +25 °C) | 18 A |
| DCR typical @ +25 °C | 4.1 mOhm |
| DCR maximum @ +25 °C | 4.52 mOhm |
| SRF typical | 50 MHz |
| Rated operating voltage (across inductor) | 40 V typical |
| Package | 7.4 x 7.1 mm footprint, 5.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
High current, low profile, and a saturation curve that bends instead of breaking: this moulded inductor family was designed for the multiphase regulator environment, where the inductor spends its life between rated current and transient peak.
The typical and the maximum DCR are both quoted for a reason: production spread. A loss budget that has to hold across a build uses 4.1 mOhm as the optimistic case and plans against the maximum.
Isat is the peak current for approximately 30% rolloff at +25 °C. Because the rolloff is gradual, the useful design question is not "what happens at Isat" but "how much inductance do I still have at my transient peak" - and the soft curve answers that with a usable number.
The two Irms columns are the same winding at two allowed self-heating levels: +20 °C for boards with a tight thermal budget, +40 °C when the enclosure has airflow or headroom. Pick the column that matches the board, not the bigger number.
EXL is the high-current moulded family for VRMs, multiphase regulators and point-of-load converters: soft-saturating alloy powder cores, low DCR, shielded, from a 4.6 mm footprint at 2.1 mm up to a 12.2 mm body at 10 mm.
What is the difference between OCL and FLL?
OCL is measured at zero bias; FLL is the inductance at Isat. Use FLL for ripple calculations at full load - that is what the converter actually sees.
What is the difference between OCL and FLL?
OCL is measured at zero bias; FLL is the inductance at Isat. Use FLL for ripple calculations at full load - that is what the converter actually sees.
Why does the SRF matter so much here?
These parts reach tens of MHz of self-resonance - far above the converter switching frequency - so the inductor behaves as an inductor across the whole operating band.
Design note: use FLL for ripple at load, the +20 °C Irms column for tight thermal budgets, and keep the transient peak inside the soft part of the saturation curve.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd