| Parameter | Value |
|---|---|
| Orderable part number | EXL1V0605-4R7-R |
| OCL | 4.7 uH ±20% |
| FLL minimum (at Isat) | 2.63 uH |
| Irms typical, +20 °C rise | 6.5 A |
| Irms typical, +40 °C rise | 8.5 A |
| Isat (30% rolloff @ +25 °C) | 8.4 A |
| DCR typical @ +25 °C | 16.7 mOhm |
| DCR maximum @ +25 °C | 18.4 mOhm |
| SRF typical | 22 MHz |
| Rated operating voltage (across inductor) | 40 V typical |
| Package | 7.4 x 7.1 mm footprint, 5.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
A moulded power inductor built around an alloy powder core: the soft-saturation curve is the headline behaviour. Where ferrite falls off a cliff past Isat, the powder core drops gradually - the inductance degrades smoothly with current instead of collapsing, which is exactly what a multiphase VRM wants from its output inductors during a load transient.
The typical and the maximum DCR are both quoted for a reason: production spread. A loss budget that has to hold across a build uses 16.7 mOhm as the optimistic case and plans against the maximum.
Saturation on a powder core is a curve, not a cliff: Isat is the peak current for approximately 30% rolloff at +25 °C, and beyond it the inductance continues to fall smoothly. Budget the transient peak against the inductance you actually need, not against the part surviving.
The two Irms columns are the same winding at two allowed self-heating levels: +20 °C for boards with a tight thermal budget, +40 °C when the enclosure has airflow or headroom. Pick the column that matches the board, not the bigger number.
EXL is the high-current moulded family for VRMs, multiphase regulators and point-of-load converters: soft-saturating alloy powder cores, low DCR, shielded, from a 4.6 mm footprint at 2.1 mm up to a 12.2 mm body at 10 mm.
What is the difference between OCL and FLL?
OCL is measured at zero bias; FLL is the inductance at Isat. Use FLL for ripple calculations at full load - that is what the converter actually sees.
What is the difference between OCL and FLL?
OCL is measured at zero bias; FLL is the inductance at Isat. Use FLL for ripple calculations at full load - that is what the converter actually sees.
What is the rated operating voltage?
The voltage the part was characterised at. It is a bias condition for the saturation measurement, not a voltage the inductor blocks.
Design note: use FLL for ripple at load, the +20 °C Irms column for tight thermal budgets, and keep the transient peak inside the soft part of the saturation curve.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd