
| Parameter | Value |
|---|---|
| Orderable part number | EXL1V0707-2R2-R |
| OCL | 2.2 uH ±20% |
| FLL minimum (at Isat) | 1.23 uH |
| Irms typical, +20 °C rise | 13.2 A |
| Irms typical, +40 °C rise | 17.8 A |
| Isat (30% rolloff @ +25 °C) | 17.6 A |
| DCR typical @ +25 °C | 5.73 mOhm |
| DCR maximum @ +25 °C | 6.33 mOhm |
| SRF typical | 25 MHz |
| Rated operating voltage (across inductor) | 40 V typical |
| Package | 8.7 x 8.3 mm footprint, 7.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
Moulded construction, magnetically shielded, alloy powder core: this part packs high current into a small footprint with low DCR. The moulding makes the body rugged and the shielding keeps the switching harmonics off the rest of the board.
At 5.73 mOhm the winding dominates the loss budget at load. The moulded construction spreads that heat into the body, but the board the part sits on still decides the actual temperature rise.
Isat is the peak current for approximately 30% rolloff at +25 °C. Because the rolloff is gradual, the useful design question is not "what happens at Isat" but "how much inductance do I still have at my transient peak" - and the soft curve answers that with a usable number.
The two Irms columns are the same winding at two allowed self-heating levels: +20 °C for boards with a tight thermal budget, +40 °C when the enclosure has airflow or headroom. Pick the column that matches the board, not the bigger number.
EXL is the high-current moulded family for VRMs, multiphase regulators and point-of-load converters: soft-saturating alloy powder cores, low DCR, shielded, from a 4.6 mm footprint at 2.1 mm up to a 12.2 mm body at 10 mm.
Why two Irms columns?
The thermal rating is given for a +20 °C rise and a +40 °C rise. Use the 20 °C column when the board can only tolerate a small self-heating, the 40 °C column when the thermal budget has room.
What is the difference between OCL and FLL?
OCL is measured at zero bias; FLL is the inductance at Isat. Use FLL for ripple calculations at full load - that is what the converter actually sees.
Why two Irms columns?
The thermal rating is given for a +20 °C rise and a +40 °C rise. Use the 20 °C column when the board can only tolerate a small self-heating, the 40 °C column when the thermal budget has room.
Design note: use FLL for ripple at load, the +20 °C Irms column for tight thermal budgets, and keep the transient peak inside the soft part of the saturation curve.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd